Selection and Manufacturing of Heat Exchange Elements & Related Systems
0.2 Selection and Manufacturing of Heat Exchange Elements
1) Air-Cooled Section (Dry Type)
The air-cooled section adopts double-metal rolled finned tubes (DR-type fins). The base tubes of the heat exchange tubes are seamless round tubes, and the fins are made of aluminum AL1060-H14. The finned tubes are integrally rolled, ensuring tight bonding between fins and base tubes. This tube type features:
No contact thermal resistance;
High pressure resistance, good atmospheric corrosion resistance, and excellent mechanical vibration prevention performance;
Good mechanical properties against thermal expansion and contraction;
A considerable extended heat exchange surface, which improves the overall total heat transfer coefficient.
It avoids heat exchange efficiency attenuation caused by alternating temperature differences that may occur during shutdowns or temperature changes. Compared with other types of fins, it is more suitable for heat exchange processes under high-temperature, high-humidity, vibration, and other harsh conditions.
2) Evaporation Section (Wet Type)
The core principle for selecting heat exchange tubes in the evaporation section is to improve the heat transfer coefficient inside and outside the tubes while ensuring low flow resistance and high mechanical strength.
A large number of case applications have proven that in the heat and mass transfer process of evaporative heat exchange equipment, the film heat transfer coefficient inside the tubes is much higher than that outside the tubes. Therefore, the key is to improve the film heat transfer coefficient outside the tubes to enhance the total heat transfer coefficient. In this project, elliptical tubes with dimensions of 31.8×21.6 (mm) are used as the main heat exchange elements. The characteristics of this tube type are as follows:
The fluid inside the tube (with a special-shaped cross-section) can easily reach a turbulent state, strengthening the heat exchange process;
Large flow area inside the tube, low flow resistance, and low power consumption of conveying machinery;
Low air-side resistance, reducing the power consumption of fans;
Uniform water film coverage, avoiding the formation of dry spots and reducing the scaling rate;
The special-shaped tube has a significant effect on absorbing the expansion force inside the tube, resulting in high anti-freezing performance.
0.4 Modular Structural Design and Manufacturing
The figure above shows a flexible modular structure. This design is adopted based on the following considerations:
Structural flexibility: Eliminates internal stress during manufacturing and operation, improves the overall strength of the tube bundle, and ensures the service life of core heat exchange elements;
Increased process flow with reduced overall dimensions: Saves more than 1/2 of the floor space;
Low elbow resistance: Reduces the flow area, increases the length of a single tube, improves the internal flow velocity of the tube, and strengthens heat exchange;
Enhanced structural strength and reliability, significantly reducing manufacturing costs;
Compared with the traditional header-type structure, the multi-process tube bundle has more reasonable heat exchange distribution and a more uniform temperature gradient;
Adopts a manifold-type header, which enables the equipment to withstand higher pressure.
|
Type |
Our Company’s Manifold-Type Header |
Other Companies’ Header Type |
|
Structural Feature |
Manifold design |
Traditional header design |
0.6 Air Supply System
The fans used in the dry-wet combined evaporative air cooler are induced draft fans. Compared with forced draft fans, they have much stronger resistance to the impact of environmental crosswinds. Meanwhile, each evaporative condenser is independently designed and manufactured, with a separate shell and air channel. The start or stop of a single unit will not have an adverse impact on other units.
Considering the harsh meteorological conditions (such as cold winters and dry air) and high-humidity operating conditions at the project site, the selection of fan cylinders and blades is particularly important:
Fan cylinders and supports are made of hot-dip galvanized carbon steel;
Blades are made of hollow aluminum alloy.
This design not only meets the high air pressure requirements of the equipment’s heat exchange tube bundle but also effectively avoids cold brittleness or thermal fatigue, extending the service life.
Electric Motor
Type: Outdoor vertical waterproof motor;
Explosion-proof grade: DII CT4;
Protection grade: IP55;
Terminal insulation grade: Class F;
Terminal temperature rise grade: Class B;
Adaptability: Suitable for the natural environment of the project site;
Transmission method: Direct connection between the motor and the fan;
Vibration reduction: Shock absorbers are installed to prevent excessive vibration of the equipment and surrounding structures during fan operation.
Air Inlet Rectifier Grid
Type: High-efficiency air inlet rectifier grid;
Advantages: Large air intake volume, low air resistance (reducing fan energy consumption), no spray water splashing, and prevention of sunlight from irradiating the inside of the water tank. This design effectively maintains the operating temperature of the spray water and prevents dust accumulation and algae growth.
0.8 Spray Water System
The spray nozzle is the core component of the evaporative air cooler’s spray device. Its function is to spray cooling water onto the surface of the cooling/condensing coil, forming a water film that exchanges heat with the process fluid inside the tube. Therefore, the spray range and density of the nozzle directly affect the heat exchange efficiency of the evaporative air cooler.
Nozzles
Material: Stainless steel (S30408);
Type: Single-layer arc disk nozzles;
Advantages:
Large flow cross-section, adapting to cooling water quality under various environments;
Larger spray range, easily forming an umbrella-shaped water cover to uniformly spray cooling water onto the surface of cooling/condensing tubes, forming a thin water film for optimal cooling effect;
No water drift caused by countercurrent wind.
Spray Pipes
Specification: Galvanized steel pipes with φ76×3 (mm);
Installation: Nozzles are installed on spray pipes via threads; spray pipes are connected to the upper water header via rubber socket sleeves (facilitating quick installation and maintenance).
Spray Water Pumps
Type: Single-stage single-suction energy-saving vertical centrifugal pumps;
Adaptability: Meet the requirements of large flow and low lift for the closed cooling tower’s circulating water system;
Configuration: Motors are of Siemensbrand, equipped with Burgmann mechanical seals.
Mist Eliminator
Installation position: At the air outlet;
Material: High-efficiency PVC;
Function: Reduce water droplets carried by the wind and discharged into the atmosphere, avoiding water waste and plume pollution, thus effectively lowering the circulating water drift rate.
0.10 Spray Water Tank
A spray water storage tank with double-effect evaporative cooling is adopted (Patent No.: ZL 2019 2 1423083.X). Especially in summer, it further cools the spray water. The cooled spray water exchanges heat with the medium inside the heat exchange coil, thereby reducing the outlet temperature of the cooled medium.
Meanwhile, for environments with poor water quality and high atmospheric dust content, the pre-cooling filler also plays a role in sedimentation and sand removal, reducing the cleaning frequency of the heat exchange coil.
Installation of pre-cooling filler: Inside the detachable louver (facilitating inspection and maintenance);
Liquid level control: A remote liquid level gauge is installed in the spray water tank; water replenishment and liquid level are controlled by a solenoid valve;
Tank bottom design: High-low tank bottom (facilitating dirt cleaning).
0.12 Spray Water Pumps
Type: Single-stage single-suction energy-saving vertical centrifugal pumps;
Adaptability: Meet the requirements of large flow and low lift for the closed cooling tower’s circulating water system;
Configuration: Motors are of Siemensbrand, equipped with Burgmann mechanical seals;
Water replenishment: The system adopts a stainless steel automatic water replenishment float valve;
Tank bottom design: High-low tank bottom (facilitating dirt cleaning).
0.14 Anti-Corrosion of Heat Exchange Tube Bundles and Support Frames
The main components such as heat exchange modules are treated with hot-dip galvanizing (thickness: 80~120μm, weight: approximately 600~900g/㎡). This treatment provides high corrosion resistance, making it an ideal protection method for products used in harsh corrosive environments, thus significantly extending the service life of the equipment.
|
Zinc Coating Weight |
Service Life (a) – Heavy Industrial Areas |
Service Life (a) – Coastal Areas |
Service Life (a) – Agricultural & Forestry Areas |
Service Life (a) – Urban Areas |
|
400 g/m² |
11.6 |
29.0 |
50.7 |
22.9 |
|
500 g/m² |
13.7 |
36.0 |
62.5 |
28.1 |
|
600 g/m² |
17.4 |
43.9 |
66.6 |
34.0 |
0.16 Equipment Shell
The equipment shell is made of aluminum-zinc coated steel plates. The protective film of the aluminum-zinc coated steel plate has extremely strong corrosion resistance to “salt”, with a service life of over 25 years. The corrosion resistance of flat surfaces is 15 times that of galvanized steel plates. It has a unique self-healing corrosion protection performance for cut surfaces. Its corrosion protection effect has been successfully verified for more than 20 years in high-humidity, high-salt, and corrosive environments such as chemical enterprises and coastal areas.
Manufacturing process:
Cut, bent, and punched by automatic CNC machines;
Assembled without welding (ensuring precise and flat dimensions);
External surface treated with electrostatic spraying;
Full automatic CNC stamping, bending, and weld-free assembly (no damage during the assembly process).
Material advantages: The aluminum-zinc coated steel plate is a hypereutectic composition with aluminum content. Its corrosion resistance is 15 times that of ordinary galvanized steel plates.
Especially in harsh corrosive environments, it maintains the original appearance of the steel plate, reducing the post-processing procedures of ordinary steel and lowering subsequent use costs.
Main Technical Parameters Table
|
No. |
Item |
Unit |
E0307 Oil-Gas Cooler |
|
1 |
Thermal Calculation Results |
– |
Thermal Calculation Results |
|
1.1 |
Site Elevation |
m |
~100 |
|
1.2 |
Design Wet Bulb Temperature |
℃ |
28 |
|
1.3 |
Tube-Side Medium Name |
– |
Aromatic vapor, hydrogen, hydrogen sulfide, etc. |
|
1.4 |
Medium Inlet Temperature |
℃ |
160 |
|
1.5 |
Medium Outlet Temperature |
℃ |
40 |
|
1.6 |
Medium Inlet Pressure |
MPa.g |
2.55~3.33 |
|
1.7 |
Tube-Side Pressure Drop |
kPa |
14.985 |
|
1.8 |
Inlet/Outlet Gas Phase Fraction |
– |
0.9517/0.1225 |
|
1.9 |
Calculated Heat Dissipation |
kW |
4465.92 |
|
1.10 |
Design Pressure |
MPa.g |
3.85 |
|
1.11 |
Test Pressure |
MPa.g |
4.8 |
|
1.12 |
Design Temperature |
℃ |
180 |
|
1.13 |
Total Rated Operating Power |
kW |
27.5 |
|
2 |
Equipment Overview |
– |
Equipment Overview |
|
2.1 |
Equipment Type |
– |
Dry-Wet Combined Evaporative Air Cooler |
|
2.2 |
Equipment Model |
– |
EAC-F-5-3-4 |
|
2.3 |
Equipment Overall Dimensions |
mm |
5630×3160×~5000 |
|
2.4 |
Calculated Number of Equipment |
Unit |
1 |
|
3 |
Heat Exchange Elements |
– |
Heat Exchange Elements |
|
3.1 |
Air-Cooled Section |
– |
Air-Cooled Section |
|
3.2 |
Finned Tube Type |
– |
L-Type Finned Tube |
|
3.3 |
Heat Exchange Tube Base Tube Specification |
– |
Φ25×2 |
|
3.4 |
Heat Exchange Tube Fin Specification |
mm |
φ57 |
|
3.5 |
Heat Exchange Tube Base Tube Material |
– |
S32168 |
|
3.6 |
Heat Exchange Base Tube Standard |
– |
GB13296-2013 (National Standard of China) |
|
3.8 |
Heat Exchange Tube Fin Material |
– |
AL-1060 |
|
3.9 |
Evaporation Section |
– |
Evaporation Section |
|
3.10 |
Heat Exchange Tube Type |
– |
Seamless Round Tube |
|
3.11 |
Heat Exchange Tube Cross-Section Dimension |
mm |
φ25 |
|
3.12 |
Heat Exchange Tube Wall Thickness |
mm |
2 |
|
3.13 |
Heat Exchange Tube Material |
– |
S32168 |
|
3.14 |
Heat Exchange Tube Standard |
– |
GB13296-2013 (National Standard of China) |
|
3.15 |
Anti-Corrosion Method |
– |
None |
|
4 |
Heat Exchange Tube Bundles |
– |
Heat Exchange Tube Bundles |
|
4.1 |
Tube Bundle Type |
– |
Serpentine Coil Structure |
|
4.2 |
Header Type |
– |
Manifold-Type Header |
|
4.3 |
Number of Tube Bundles |
– |
4 |
|
4.4 |
Header Material/Anti-Corrosion Method |
– |
S32168 |
|
4.5 |
Frame Material |
– |
Q235B, Hot-Dip Galvanized |
|
5 |
Air Supply System |
– |
Air Supply System |
|
5.1 |
Fan Type |
– |
Induced Draft Axial Fan |
|
5.2 |
Number of Fans |
Unit |
2 |
|
5.3 |
Impeller Diameter |
mm |
2200 |
|
5.4 |
Air Volume per Fan |
m³/h |
150000 |
|
5.5 |
Fan Static Pressure |
Pa |
220 |
|
5.6 |
Blade Material |
– |
Aluminum Alloy |
|
5.7 |
Fan Cylinder Material |
– |
Q235B, Hot-Dip Galvanized |
|
5.9 |
Transmission Type |
– |
Direct Connection |
|
5.10 |
Motor Power |
kW |
15 |
|
5.11 |
Motor Power Supply |
– |
380V/3Ph/50Hz |
|
5.12 |
Protection Grade |
– |
IP55 |
|
5.13 |
Explosion-Proof Grade |
– |
Ex dII CT4 |
|
5.14 |
Insulation Grade |
– |
H |
|
5.15 |
Temperature Rise Grade |
– |
F |
|
5.16 |
Speed Regulation Method |
– |
Frequency Conversion |
|
6 |
Spray Water System (Per Unit) |
– |
Spray Water System (Per Unit) |
|
6.1 |
Spray Pipe Specification & Material |
– |
DN65, S30408 |
|
6.2 |
Nozzle Specification & Material |
– |
3/4″, S30408 |
|
6.3 |
Water Collector Specification |
– |
Aluminum Alloy |
|
6.4 |
Spray Water Pump Type |
– |
Cooling Tower-Specific Centrifugal Pump |
|
6.5 |
Number of Spray Water Pumps |
Unit |
2 (50% Standby) |
|
6.6 |
Pump Flow Rate |
m³/h |
233 |
|
6.7 |
Pump Head |
m |
5 |
|
6.8 |
Pump Power |
kW |
5.5 |
|
6.9 |
Pump Motor Power Supply |
– |
380V/3Ph/50Hz |
|
6.10 |
Protection Grade |
– |
IP55 |
|
6.11 |
Explosion-Proof Grade |
– |
Ex dII CT4 |
|
6.12 |
Insulation Grade |
– |
F |
|
6.13 |
Temperature Rise Grade |
– |
B |
|
7 |
Other Components Material |
– |
Other Components Material |
|
7.1 |
Support Frame |
– |
Q235B, Hot-Dip Galvanized |
|
7.2 |
Outer Shield Plate |
– |
Magnesium-Aluminum-Zinc Coated Steel Plate |
|
7.3 |
Water Collection Tank |
– |
S30408 |
|
7.4 |
Air Inlet Rectifier Grid |
– |
Magnesium-Aluminum-Zinc Coated Steel Plate |
|
7.5 |
Water Replenishment Device |
– |
Float Valve, S30408 |
|
7.6 |
Fasteners |
– |
Hot-Dip Galvanized, Grade 8.8 |
|
7.7 |
Water Tank Filter Screen |
– |
S30408 |
|
7.8 |
Spray Water Supply Pipe |
– |
S30408 |
|
8 |
Nozzle Detail List (HG/T 20592-2009, WN, Series B, RF) |
– |
Nozzle Detail List (HG/T 20592-2009, WN, Series B, RF) |
|
8.1 |
Medium Inlet |
– |
4-DN100, PN63 |
|
8.2 |
Medium Outlet |
– |
4-DN100, PN63 |
|
8.3 |
Purge & Drain Port |
– |
DN25, PN63 |
|
8.4 |
Overflow Port |
– |
DN50, PN10 |
|
8.5 |
Water Replenishment Port |
– |
DN50, PN10 |
|
8.6 |
Drain Port |
|
|